What was found
DURING THE JACKING PROCESS THE FOLLOWING DAMAGE OCCURRED AT STATION 287, BETWEEN S25R AND S27R (AT LAP SPLICE), BOTH UPPER AND LOWER SKINS WERE DAMAGED. STA 287 BULKHEAD OUTER CHORD WAS BENT, WITH THE ATTACHING WEB ALSO DISTORTED. *S/D* ACCOMPLISHED A VISUAL INSPECTION INSIDE THE EQUIPMENT BAY AREA BEHIND THE P-37 PANEL USING BOROSCOPE FLEX PROBE IN ACCORDANCE WITH NDT MANUAL 51-00-01. NO CRACKS OR DEFECTS NOTED. CREATED MAINTENANCE ITEM TO PERFORM A REPETITIVE ''A'' CHECK EXTERNAL SKIN VISUAL INSPECTION TO ENSURE NO CRACKS EXIST AND NO EVIDENCE OF PULLED OR LOOSE FASTENERS. STA 287 BULKHEAD WEB AND EXTERNAL SKIN PERMANENTLY REPAIRED PER EVA IMC-00415(MRA-113) AND SRM 53-00-01 AT ''C'' CHECK.