What was found
EMERGENCY EXIT LIGHTING CAME ON. RECYCLED POWER FAILURE CIRCUIT BREAKER AND LIGHTS WENT OUT. *S/D* REPLACED R70 POWER FAIL RELAY. OPERATIONAL CHECK OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EMERGENCY EXIT LIGHTING CAME ON. RECYCLED POWER FAILURE CIRCUIT BREAKER AND LIGHTS WENT OUT. *S/D* REPLACED R70 POWER FAIL RELAY. OPERATIONAL CHECK OK.