What was found
A 36 X 4 INCH TEAR, 3 FEET BELOW DOOR 1 RIGHT. *S/D* FUSELAGE SKIN WAS DAMAGED BY GROUND SERVICE EQUIPMENT. REPAIRED SHEAR TIE AT BS 312, REFERENCE STRUCTURAL REPAIR MANUAL (SRM) 53-00-07. INSTALLED NEW FRAME SPLICE AT BS 328, REFERENCE SRM 51-70-11. REPAIRED CHORD AT BS 328, REFERENCE SRM 51-70-11. EXTERNAL FUSELAGE SKIN REPAIR WAS INSTALLED PER SRM 53-00-001 AND EVA ORD-5584. THIS IS CONSIDERED A MAJOR REPAIR (MRA 117).