As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BOTH PUMPS ON THE A HYDRAULIC SYSTEM WERE INDICATING OVERHEAT. CONTINUED TO DEN AND AMBER ALERT DECLARED. AIRCRAFT TOWED TO GATE. SUPPLEMENTAL DATA UPDATE FOUND HYDRAULIC RUDDER MODULE BYPASSING. REPLACED MODULE AND RELATED COMPONENTS PER MAINTENANCE MANUAL. RESERVICED HYDRAULIC SYSTEM. OPS CHECK OK.