What was found
LONGERON 6R STATION 1490 TO 1600 HAS AREAS OF EXFOLIATION. REMOVED CORROSION IAW DC-8 SRM 51-1-8. TREATED, PRIMED AND REPAIR PER DC-8 SRM 53-2-2 PAGE 59/60 PER EO NR 99-136 WITH APPROVED 8110-3 DATED 8/11/99. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LONGERON 6R STATION 1490 TO 1600 HAS AREAS OF EXFOLIATION. REMOVED CORROSION IAW DC-8 SRM 51-1-8. TREATED, PRIMED AND REPAIR PER DC-8 SRM 53-2-2 PAGE 59/60 PER EO NR 99-136 WITH APPROVED 8110-3 DATED 8/11/99. (M)