What was found
FLOORBEAM 38 HAS CORROSION AROUND SCREW HOLES UPPER AND LOWER SURFACES. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 51-21-42. REMOVED AND INSTALLED FLOORBEAM IAW SRM 51-25-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM 38 HAS CORROSION AROUND SCREW HOLES UPPER AND LOWER SURFACES. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 51-21-42. REMOVED AND INSTALLED FLOORBEAM IAW SRM 51-25-01. (M)