What was found
FRAME 38, CORRODED AROUND NTU PLATED. BLENDED CORROSION AND FOUND TO BE BEYOND LIMITS IAW SRM 53-00-00. REMOVED AND INSTALLED FLOORBEAM SECTION AND PERFORMED SPLICE IAW SRM 53-00-00 FIG 435. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME 38, CORRODED AROUND NTU PLATED. BLENDED CORROSION AND FOUND TO BE BEYOND LIMITS IAW SRM 53-00-00. REMOVED AND INSTALLED FLOORBEAM SECTION AND PERFORMED SPLICE IAW SRM 53-00-00 FIG 435. (M)