What was found
FLOORBEAM NR 36 LEFT STANCHION HAS CORROSION AROUND GROUND SCREW HOLE. BLENDED CORRODED AREAS IAW SRM 51-21-58. REMOVED AND INSTALLED STANCHION IAW ATR SRM 51-25-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM NR 36 LEFT STANCHION HAS CORROSION AROUND GROUND SCREW HOLE. BLENDED CORRODED AREAS IAW SRM 51-21-58. REMOVED AND INSTALLED STANCHION IAW ATR SRM 51-25-01. (M)