What was found
DURING COURSE OF 10,000-HOUR INSPECTION, THE HORIZONTAL STABILIZER WAS FOUND TO HAVE NUMEROUS DOUBLE HOLES, HOLES DRILLED OFF-CENTER, HOLES DRILLED ON AN ANGLE AFTER REMOVAL OF THE HYLOCKS IN THE CENTER SECTION THROUGH ALL SPARS AND FITTINGS. SUBMITTER STATED IT IS VERY OBVIOUS A MANUFACTURING PROBLEM.