What was found
SUGAR SCOOP CORRODED (OUTFLOW VALVE) STA 1323. REMOVED CORROSION IAW DC-8 SRM 51-1-8. WELDED AREA, NDT TO ASSURE NO FLAWS (NONE FOUND) BLEND SMOOTH AND FINISHED PER FACTORY SPECS PER EO 99-136 WITH APPROVED 8110-3 DATED 8-14-99. REF: ZANTOP INTERNATIONAL AIRLINES, INC., ZIAA. (X)