What was found
ONE SHEARED RIVET, ONE LOOSE RIVET AND AREA CORRODED UNDER PANEL STATION 789-809 STRINGER 29-38 FOUND DURING C-CHECK. LOWER FRAME REPAIR CARRIED OUT IAW SRM 51-50-02 FIG 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ONE SHEARED RIVET, ONE LOOSE RIVET AND AREA CORRODED UNDER PANEL STATION 789-809 STRINGER 29-38 FOUND DURING C-CHECK. LOWER FRAME REPAIR CARRIED OUT IAW SRM 51-50-02 FIG 2. (M)