What was found
DURING C-CHECK, FOUND 1 INCH CRACK IN RADIUS OF AFT CHORD OF BS 1183 VERTICAL BEAM RBL 36, 29 INCHES FROM CABIN FLOOR. STOP DRILLED CRACK AND INSTALLED DOUBLER REPAIR IAW SB 727-53-192. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK, FOUND 1 INCH CRACK IN RADIUS OF AFT CHORD OF BS 1183 VERTICAL BEAM RBL 36, 29 INCHES FROM CABIN FLOOR. STOP DRILLED CRACK AND INSTALLED DOUBLER REPAIR IAW SB 727-53-192. (M)