What was found
SAW - DURING CPCP-2 INSPECTION MAINTENANCE REPORTED THE LEFT INTERCOSTAL BETWEEN FRAMES 36 AND 38 CORRODED, THE LEFT FLOOR SUPPORT BETWEEN FRAMES 38 AND 39 CORRODED. THE RIGHT INTERCOSTAL BETWEEN FRAMES 36 AND 38 CORRODED, AND TEH SERVICE DOOR DRAIN TRACK BETWEEN FRAMES 36 AND 39 CORRODED. MAINTENANCE REMOVED AND REPLACED THE INTERCOSTALS, FLOOR SUPPORT, AND DRAIN TRACK IAW SRM 51-25-02. AIRCRAFT WAS RETURNED TO SERVICE. REF SIMA07813. (M)