What was found
STRINGER 38R SPLICE AT STATION 434 HAS AN ELONGATED HOLE FOR STRINGER CLIP. *S/D* MAJOR REPAIR ACCOMPLISHED. REPLACED SPLICE PER SRM 53-30-03 AND 51-40-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRINGER 38R SPLICE AT STATION 434 HAS AN ELONGATED HOLE FOR STRINGER CLIP. *S/D* MAJOR REPAIR ACCOMPLISHED. REPLACED SPLICE PER SRM 53-30-03 AND 51-40-2.