What was found
AFT PIT, BS 1131, LBL 43-49, STRAP ON TOP OF FLOORBEAM CORRODED. FABRICATED NEW T-CAP PER BAC DWG 146T1203 AND INSTALLED PER SRM 51-40-2. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT, BS 1131, LBL 43-49, STRAP ON TOP OF FLOORBEAM CORRODED. FABRICATED NEW T-CAP PER BAC DWG 146T1203 AND INSTALLED PER SRM 51-40-2. MAJOR REPAIR.