What was found
BODY STATION 287 RBL 55 FLOORBEAM CORRODED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED FLOORBEAM REPAIR IN ACCORDANCE WITH SRM 53-00-51.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BODY STATION 287 RBL 55 FLOORBEAM CORRODED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED FLOORBEAM REPAIR IN ACCORDANCE WITH SRM 53-00-51.