What was found
FLOORBEAM CORRODED AT STATION 1197, RBL 15, AFT CARGO COMPARTMENT. MAJOR REPAIR ACCOMPLISHED. INSTALLED T-CAP AND DOUBLER REPAIR ON FLOORBEAM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM CORRODED AT STATION 1197, RBL 15, AFT CARGO COMPARTMENT. MAJOR REPAIR ACCOMPLISHED. INSTALLED T-CAP AND DOUBLER REPAIR ON FLOORBEAM.