What was found
CABIN FLOORBEAM UPPER SURFACE OF UPPER CAP HAD GOUGE AT STATION 640 STRINGER 17R AT 12 RBL TO 20 RBL. MAJOR REPAIR ACCOMPLISHED. BLENDED OUT GOUGE AND AFT. INSTALLED TWO TAPERED STRAPS BELOW FWD AND AFT.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOORBEAM UPPER SURFACE OF UPPER CAP HAD GOUGE AT STATION 640 STRINGER 17R AT 12 RBL TO 20 RBL. MAJOR REPAIR ACCOMPLISHED. BLENDED OUT GOUGE AND AFT. INSTALLED TWO TAPERED STRAPS BELOW FWD AND AFT.