What was found
DURING B-CHECK, A CRACKED FLOOR PANEL ATTACH HOLE COMMON TO THE BS 380 UPPER DECK FLOORBEAM UPPER CHORD WAS DISCOVERED P/N 65B10929-18 AT RBL 65.0. THE CRACKED UPPER CHORD IS BEING REPAIRED BY INSTALLING 2 STRAPS PER ECRA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING B-CHECK, A CRACKED FLOOR PANEL ATTACH HOLE COMMON TO THE BS 380 UPPER DECK FLOORBEAM UPPER CHORD WAS DISCOVERED P/N 65B10929-18 AT RBL 65.0. THE CRACKED UPPER CHORD IS BEING REPAIRED BY INSTALLING 2 STRAPS PER ECRA.