What was found
FOUND CORROSION ON FLOOR SUPPORT BS 1675, RBL 56, WL 208. CLEANED UP CORROSION, FOUND TO BE BEYOND ACCEPTABLE LIMITS PER SRM 53-00-01. REMOVED AND REPLACED SUPPORT. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND CORROSION ON FLOOR SUPPORT BS 1675, RBL 56, WL 208. CLEANED UP CORROSION, FOUND TO BE BEYOND ACCEPTABLE LIMITS PER SRM 53-00-01. REMOVED AND REPLACED SUPPORT. (M)