What was found
DURING SCHEDULED INSPECTION LEVEL 2 CORROSION DISCOVERED ON CABIN FLOORBEAM UPPER CAP, FS 901, WL 200, LBL 115 TO RBL 14. MAINTENANCE REPAIRED THE FLOORBEAM IN ACCORDANCE WITH LOCKHEED SRM 53-21-00, FIGURE 815.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED INSPECTION LEVEL 2 CORROSION DISCOVERED ON CABIN FLOORBEAM UPPER CAP, FS 901, WL 200, LBL 115 TO RBL 14. MAINTENANCE REPAIRED THE FLOORBEAM IN ACCORDANCE WITH LOCKHEED SRM 53-21-00, FIGURE 815.