What was found
DURING CURRENT C-CHECK AT SIAEC, FOUND RT WING L/E STATIONS NR ILES 378, 400, 446, 467, AND 546 NOSE CAP POSITIONS CRACKED AND CORRODED AT TOP ROW OF RIVETS. SIX CRACKED/ CORRODED AREAS TRIMMED OUT. ALL AREAS HFEC INSPECTED FOR ADDITIONAL CRACKS. NONE FOUND. FABRICATED FILLER, INTERNAL REPAIR DOUBLER AND TAPERED SHIMS FOR EACH AREA. OVERSIZED EXISTING HOLES. INSTALLED REPAIR SECTIONS IAW SRM 57-30-04 FIG 2 AT ILES 378, 400, 446, 467, 515 AND 546. (M)