What was found
FOUND DURING DOUGLAS D-CHECK INSPECTION, LIGHT SURFACE CORROSION ON LOWER CENTER FUSELAGE AREA BETWEEN CENTER WING STRINGERS 67 AND 68 5 INCHES RIGHT OF ECWO. CORROSION OUT OF LIMITS STATION 759-768, 6 INCHES RIGHT OF CENTER LINE, ITEM 4 ON FORM 84. REMOVED CORROSION. FABRICATED DOUBLER TREATED, PRIMED AND INSTALLED DOUBLER. ALL WORK ACCOMPLISHED PER EO NR 02-039 REV A WITH APPROVED 8110-3. (M)