FOUND DURING DOUGLAS D-CHECK INSPECTION, RIGHT INBOARD FLAP INBOARD WEB HAS PREVIOUS REPAIR CRACK EXTENDS TO NEW STOP DRILL AT END OF CRACK BEYOND REPAIR DOUBLER. STOP DRILLED END OF CRACK IAW DC-8 SRM 57-2-0. FABRICATED DOUBLER IAW DC-8 SRM 57-2-0, FIG 2. TREATED, PRIMED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-8, 51-1-21 AND 51-3-0. (M)