As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING CURRENT D-CHECK AT SIAEC, FOUND STATION 440L FRAME CRACKED AT CUT OUT OF STRINGER 10A. CRACK LENGTH .1875. STOP DRILLED CRACK, FABRICATED REPAIR DOUBLRS AND INSTALLED PER SRM 53-10-20 AND 53-10-04. FRAME IS SUBJECT TO RECURRENT INSPECTIONS PER SB 747-53A2265 AT 3000 CYCLES. (M)