What was found
NUMBER 1 ENGINE COMPRESSOR STALL. FOUND 10TH STAGE STATOR FAILED. THIS STATOR HAD THE NEW GOLD/NICKEL BRAZE MATERIAL AS PER PWA SERVICE BULLETIN. STATOR HAD 470 CYCLES SINCE 100 PERCENT VANE REPLACEMENT.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NUMBER 1 ENGINE COMPRESSOR STALL. FOUND 10TH STAGE STATOR FAILED. THIS STATOR HAD THE NEW GOLD/NICKEL BRAZE MATERIAL AS PER PWA SERVICE BULLETIN. STATOR HAD 470 CYCLES SINCE 100 PERCENT VANE REPLACEMENT.