What was found
AFT GALLEY DOOR CUTOUT FORWARD FUSELAGE FRAME STATION 956 IS CRACKED 1.5 IN BETWEEN STRINGER 9-10R AT UPPER LATCH ROLLER FITTING ATTACHMENT. MAJOR REPAIR ACCOMPLISHED. STUB FRAME REPLACED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT GALLEY DOOR CUTOUT FORWARD FUSELAGE FRAME STATION 956 IS CRACKED 1.5 IN BETWEEN STRINGER 9-10R AT UPPER LATCH ROLLER FITTING ATTACHMENT. MAJOR REPAIR ACCOMPLISHED. STUB FRAME REPLACED.