What was found
BODY STATION 640 BL 0 RBL 22 FLOORBEAM TOP SURFACE GOUGED. MAJOR REPAIR ACCOMPLISHED. CUT AWAY DAMAGED AREA AND INSTALLED T-CAP REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BODY STATION 640 BL 0 RBL 22 FLOORBEAM TOP SURFACE GOUGED. MAJOR REPAIR ACCOMPLISHED. CUT AWAY DAMAGED AREA AND INSTALLED T-CAP REPAIR.