CABIN FLOOR INTERCOSTAL BETWEEN STATION 324.5 AND 345 HAD EXCESSIVE MATERIAL REMOVED DURING CORROSION CLEAN UP, 3 RBL AND AT STRINGER 17R. MAJOR REPAIR ACCOMPLISHED. REPLACED INTERCOSTAL.