What was found
BELL CRANK FOUND FRACTURED ALONG WITH ADJACENT 113W1452-X PUSH ROD WITH ROD END FRACTURED. FOUND DAMAGED OVERWING FAIRING SPRT MLG BODY DOOR STOP STRUCTURE INSTL (49W4172-2,149W4175-1). MINOR DAMAGE (GOUGE TO INSIDE WALL OF I/B FLAP TRACK ON I/B FLAP). CLIP & ADJACENT RIB ON ADJACENT FAIRING DAMAGED. I/B LT FLAP WAS EXTENDED INTO GSE EQUIP CAUSING DAMAGE TO FLAP T/E & CANOE FAIRING. AT THIS TIME, UAL SUSPECTS THAT IMPACT TO FLAP CAUSED PARTIAL OR FULL FRACTURE OF BELL CRANK. ANOTHER OPERATOR REPORTED A FRACTURED BELL CRANK AND BROKEN FLAP, INBOARD TRACK. PARTS ARE BEING SENT TO UAL METALLURGIST TO DETERMINE MORE ABOUT HOW THE PARTS FRACTURED.