What was found
CABIN FLOORBEAM STATION 986 RIGHT HAND OUTBOARD WAS CORRODED WITH EXCESSIVE MATERIAL REMOVED. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE, INSTALLED REPAIR ANGLE AND FILLERS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOORBEAM STATION 986 RIGHT HAND OUTBOARD WAS CORRODED WITH EXCESSIVE MATERIAL REMOVED. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGE, INSTALLED REPAIR ANGLE AND FILLERS.