What was found
BODY STATION 348 STRINGER 20R RBL 84 TOP OF FLOORBEAM CORRODED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED FLOORBEAM SECTION AND SPLICES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BODY STATION 348 STRINGER 20R RBL 84 TOP OF FLOORBEAM CORRODED. MAJOR REPAIR ACCOMPLISHED. FABRICATED AND INSTALLED FLOORBEAM SECTION AND SPLICES.