What was found
CABIN FLOOR INTERCOSTAL AT STATION 357 RBL 25" STRINGER 17R IS CRACKED OUT AROUND NUTPLATE HOLE. MAJOR REPAIR ACCOMPLISHED.INSTALLED NEW U- CHANNEL INTERCOSTAL BETWEEN STATION 345 AND 365.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOOR INTERCOSTAL AT STATION 357 RBL 25" STRINGER 17R IS CRACKED OUT AROUND NUTPLATE HOLE. MAJOR REPAIR ACCOMPLISHED.INSTALLED NEW U- CHANNEL INTERCOSTAL BETWEEN STATION 345 AND 365.