What was found
CABIN FLOORBEAM AT BODY STATION 294 HAS EXCESSIVE MATERIAL LOSS AT RBL 44 DUE TO CORROSION REMOVAL. MAJOR REPAIR ACCOMPLISHED. REPLACED CHORD AND SPLICES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOORBEAM AT BODY STATION 294 HAS EXCESSIVE MATERIAL LOSS AT RBL 44 DUE TO CORROSION REMOVAL. MAJOR REPAIR ACCOMPLISHED. REPLACED CHORD AND SPLICES.