What was found
AFT PIT T-CAP CORRODED AT BODY STATION 1175, BL 0 TO RBL 40. MAJOR REPAIR ACCOMPLISHED. REPAIRED AND INSTALLED FLOORBEAM T-CAP.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT T-CAP CORRODED AT BODY STATION 1175, BL 0 TO RBL 40. MAJOR REPAIR ACCOMPLISHED. REPAIRED AND INSTALLED FLOORBEAM T-CAP.