What was found
CABIN FLOOR BEAM UPPER CAP HAD EXCESS MATERIAL REMOVED DURING CORROSION CLEAN UP AT STATION 680 RBL 5 TO RBL 12, TWO SPOTS STRINGER 17R. MAJOR REPAIR ACCOMPLISHED. INSTALLED STRAP REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.