What was found
AT C-CHECK, FOUND CORROSION ON TOP OF FLOORBEAM AT STATION 1130, RBL 45. REMOVED UPPER T-CAP FROM LBL 60 TO RBL 60. FABRICATE, TREAT, PRIME AND INSTALLED NEW T-CAP. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, FOUND CORROSION ON TOP OF FLOORBEAM AT STATION 1130, RBL 45. REMOVED UPPER T-CAP FROM LBL 60 TO RBL 60. FABRICATE, TREAT, PRIME AND INSTALLED NEW T-CAP. (M)