What was found
AT C-CHECK, FOUND CORROSION ON FLOORBEAM, STATION 328 RBL 10, UNDERNEATH NUTPLATE. REMOVED CORROSION. MATERIAL LOSS OTU OF LIMITS. FABRICATED ONE EACH END CAP AND 4 ANGLES. TREATED, PRIMED AND INSTALLED REPAIRED PARTS. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT C-CHECK, FOUND CORROSION ON FLOORBEAM, STATION 328 RBL 10, UNDERNEATH NUTPLATE. REMOVED CORROSION. MATERIAL LOSS OTU OF LIMITS. FABRICATED ONE EACH END CAP AND 4 ANGLES. TREATED, PRIMED AND INSTALLED REPAIRED PARTS. (M)