As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PROPELLER WAS REMOVED AND SENT TO PIEDMONT AVIATION COMPONENT SERVICES (REPAIR STATION QWPR503X) FOR MCCAULEY ALERT SERVICES BULLETIN 246B/REV 2 INSPECTION. DURING FLUORESENT PENETRANT INSPECTION FOUND NR 1 BLADE P/N 114HCA-0, S/N PE006 (TSN 13,090.01; TSO 1,205.41) WITH AN INDICATION PER MCCAULEY ASB 246/REV 2.