What was found
WHEN PERFORMING A FULL STALL LANDING THE TAIL TIE DOWN STRUCK THE GROUND (RATHER HARD). INSPECTION FOUND NO DAMAGE OTHER THAN SCUFFING OF THE TIE DOWN RING. FOUND ALL FIVE NUTS AND BOLTS TO BE TIGHT TO BOTH FINGER PRESSURE AND WRENCH, COMPLIENCE WITH AD. WHILE CLEANING AREA AROUND RT RUDDER CABLE HOLE, A POSSIBLE CRACK WAS NOTED AND CONFIRMED. CRACK ORIGINATED AT APPROX 11 OCLOCK ON THE HOLE, RADIATING OUTWARD AND UPWARD APPROX .3125 INCH, TO A POINT APPROX .1875 INCH FROM UPPER CURVE AT BULKHEAD FLANGE. STRIKE ON TIE DOWN RING WAS A DIRECT CONTRIBUTOR TO THE DAMAGE FOUND.