Service difficulty report · Valve

Difficulty date
April 4, 2003
Submitted
July 29, 2003
Operation
General aviation
System (JASC)
2564 · Life Raft
Part
Valve
Condition
Improper Part
Location
Life Raft
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WHILE CONDUCTING PART 135 TRAINING OF LIFE RAFT DEPLOYMENT USING A SWITLIK FOUR-MAN LIFE RAFT, THE RAFT FAILED TO INFLATE. IT WAS DISCOVERED THAT .020 STAINLESS STEEL SAFETY WIRE, INSTALLED ON THE BOTTLE VALVE, PREVENTED INFLATION OF THE RAFT. THE VALVE SHOUD HAVE BEEN SAFETIED WITH .020 SOFT COPPER SAFETY WIRE. INVESTIGATION FOUND THAT BOTTLE HAD RECENTLY BEEN RECHARGED. WE IMMEDIATELY BEGAN INSPECTING THE REST OF THE FOUR-MAN RAFTS IN OUR FLEET AND HAVE FOUND 6 BOTTLE VALVES THUS FAR WITH .020 STAINLESS STEEL SAFETY WIRE INSTALLED.