Service difficulty report · Button · Emb EMB135ER

Difficulty date
September 26, 2003
Submitted
October 3, 2003
Operation
General aviation
Make and model
Emb EMB135ER
Part
Button
Part number
60277
Condition
Cracked
Location
Filter Module
Component
Apu · Hamltn
Component part number
APS500R
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

INDICATOR BUTTON FAILURE OCCURED ON THREE UNITS AND CRACKS CLEARLY EVIDENT ON TWO OTHERS IN SAME AREA OF BREAKAGE. ONCE BROKEN, A SECTION OF THE BUTTON CAN TRAVEL BEYOND THE SEALED AREA OF THE HOUSING AND HAS THE CAPABILITY OF ALLOWING A FUEL LEAK OF UP TO 1.5 GALLONS PER MINUTE. ENGINEERING ANALYSIS INDICATES A LOW CYCLE FATIGUE SITUATION (FATIGUE CRACKS VISIBLE WITH A MICROSCOPE EXAM AT 7-30X). CEP PERFORMED A FEA SIMULATING THE BUTTON RESTRAINED IN THE CAP HOUSING WHICH SHOWS THE FAILURE TO BE IN THE LOW CYCLE FATIGUE REGION FOR 7075-T6 ALUMINUM. FUEL FILTER MODULE, PN 60500 & PN 4951960 / SN`S: C0072, C0213, C0383, C0390, C0528