As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CRACKED FRAMES AT TB/VERTICAL FIN JUNCTION. ADDITIONALLY THE VERTICAL FIN STRUCTURE IS CRACKED AS WELL. THIS IS THE SECOND SHIP IN THE LAST 90 DAYS THAT HAS HAD THIS SAME DAMAGE FOUND. THE SRM DETAILS THE INDICATIONS AND REPAIR FOR THE FRAMES. AUGUSTA PROVIDED DATA FOR THE VERTICAL FIN REPAIR. THIS REPORT IS SUBMITTED IAW OUR IPM AND AS REQUIRED BY 14 CFR 145.63.