What was found
B-HYDRAULIC SYSTEM QUANTITY AND PUMP LOW PRESSURE LIGHTS ILLUMINATED. INSPECTION FOUND THAT THE RETURN LINE CHECK VALVE FITTING ON THE HYDRAULIC FLAP DRIVE MOTOR SHEARED OFF AT THE BOSS. THE FITTING WAS REPLACED. THE HYDRAULIC SYSTEM WAS SERVICED AND THE FILTERS WERE CHANGED. OPERATIONAL CHECKS OF ALL PUMPS ASSOCIATED WITH SYSTEM 'B' AND NR 2 ENGINE RUN WAS ACCOMPLISHED TO VERIFY 'B' SYSTEM HYDRAULICS OPERATE NORMALLY.