Service difficulty report · Fitting · Boeing 737522

Difficulty date
May 24, 2003
Submitted
June 3, 2003
Operation
Air carrier
Aircraft
N901UA
Make and model
Boeing 737522
Aircraft serial
25001
Aircraft time
35,371 hours, 22,870 cycles
Engine
Ge CFM56*
Part
Fitting
Condition
Leaking
Location
Hyd System
Stage of operation
CR
How discovered
O
Nature of condition
K, J
Precautionary procedure
A, H

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

B-HYDRAULIC SYSTEM QUANTITY AND PUMP LOW PRESSURE LIGHTS ILLUMINATED. INSPECTION FOUND THAT THE RETURN LINE CHECK VALVE FITTING ON THE HYDRAULIC FLAP DRIVE MOTOR SHEARED OFF AT THE BOSS. THE FITTING WAS REPLACED. THE HYDRAULIC SYSTEM WAS SERVICED AND THE FILTERS WERE CHANGED. OPERATIONAL CHECKS OF ALL PUMPS ASSOCIATED WITH SYSTEM 'B' AND NR 2 ENGINE RUN WAS ACCOMPLISHED TO VERIFY 'B' SYSTEM HYDRAULICS OPERATE NORMALLY.