What was found
BS 1361-1379 STRINGER SECTION REQUIRES REPLACEMENT IN ORDER TO MAINTAIN 20 INCH MINIMUM SPACING BETWEEN STRINGER SPLICE AT STATION 1337, STRINGER 34R. MAJOR REPAIR ACCOMPLISHED. REPLACED STRINGER SECTION AND SPLICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 1361-1379 STRINGER SECTION REQUIRES REPLACEMENT IN ORDER TO MAINTAIN 20 INCH MINIMUM SPACING BETWEEN STRINGER SPLICE AT STATION 1337, STRINGER 34R. MAJOR REPAIR ACCOMPLISHED. REPLACED STRINGER SECTION AND SPLICE.