As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING PRE-FLIGHT FOUND EXCESSIVE PLAY BETWEEN ELEVATOR TRAILING EDGES. AIRCRAFT DID NO DISPATCH. REMOVED ELEVATOR, DISASSEMBLED LEFT TORQUE TUBE. FOUND TORQUE TUBE CRACKED ALMOST 3/4 OF THE WAY AROUND THE CIRCUMFRANCE OF THE TORQUE TUBE SURFACE. INSTALLED NEW TORQUE TUBE ASSEMBLY. TORQUE TUBE TOTAL TIME 5468 HOURS. INSPECTION INTERVAL IS 1000 HOURS. NEXT INPSECTION DUE IN 451 HOURS PER SERVICE BULLETIN 21-45.