What was found
FOUND EMERGENCY LIGHTS ON AT R2 AND L2 DOORS, ONLY DURING TURBULENCE. OVER L2 DOOR, FOUND TWO WIRES INSULATION WORN AWAY MAKING CONTACT. REPAIRED WIRING IAW SWPM 20-00-00. OPS CHECKED OK. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND EMERGENCY LIGHTS ON AT R2 AND L2 DOORS, ONLY DURING TURBULENCE. OVER L2 DOOR, FOUND TWO WIRES INSULATION WORN AWAY MAKING CONTACT. REPAIRED WIRING IAW SWPM 20-00-00. OPS CHECKED OK. (M)