What was found
STR SPLICE IS CRACKED BETWEEN 2 RIVETS AT BS 907 S4L. MAJOR REPAIR ACCOMPLISHED. INSTALLED SHEAR CLIP AND STRINGER SPLICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STR SPLICE IS CRACKED BETWEEN 2 RIVETS AT BS 907 S4L. MAJOR REPAIR ACCOMPLISHED. INSTALLED SHEAR CLIP AND STRINGER SPLICE.