What was found
FRAME IS DENTED AT STATION 1440, STRINGER 25L, UPPER IB FLANGE. TYPICAL CARGO PIT DENT DAMAGE DUE TO CARGO LOADING. INSTALLED NESTED J-ANGLE REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME IS DENTED AT STATION 1440, STRINGER 25L, UPPER IB FLANGE. TYPICAL CARGO PIT DENT DAMAGE DUE TO CARGO LOADING. INSTALLED NESTED J-ANGLE REPAIR.