What was found
MYR - FLT 1581 - F/A REPORTED LIGHT TO MODERATE SMOKE IN FORWARD CABIN. INSPECTED ALL BALLASTS AND LIGHTING AND GALLEY EQUIPMENT, INSPECTED WIRING AND C/'B'S IN FORWARD CABIN, CHECKED E/E FORWARD ACCY COMPT NO EVIDENCE OF OVERHEAT, SMOKE OR FIRE FOUND, RUN A/C PACKS WITH ENGINES AND APU NO SMOKE, COULDN'T DUPLICATE. REMOVED SOCKS AND FOUND EVIDENCE OF SMOKE AND LIGHT OILY ODOR ON THE RIGHT SOCK, REMOVED AND REPLACED BOTH SOCKS. (M)